top of page

Automated sustainable SPR system for drug discovery and precise kinetics

iMSPR-ProX

Most sustainable & reasonable SPR system

Unibody fluidics module with 2-flow cells

made by CNC machining,

Kretsmann configuration based optical module,

Autosampler, degasser, solenoid selection valve, etc...

iMSPR-Pro2X_샘플러 사시도1.png
프로x 모니터.png
노트북 프로.png

Pro series common features

Sample to Answer 

After designing an experiment through the Experiment Wizard, when a sample is injected, the kinetics evaluation value can be obtained through the automatic analysis function built into the iMSPR operating software.

sample.png
Answer.png

Sustainable U-type fluidics module

Through the U-type fluidics module, the immobilization step can be shortened efficiently, and referencing can be performed perfectly without time lag. In addition, it can be used permanently since it is manufactured with a PEEK unibody.

U-type fluidics3.png

Inlet 1

Outlet

Inlet 2

U-type fluidics module

Sensor chip surface

Sample flow channel

Reference region

Ligand immobilization region

When using both channels (binding analysis)

When immobilizing the ligand

Automatic qualification check of sensor chip

The sensor chip status is checked before the experiment through the automatic check function built into the iMSPR operation software. You can secure more reliable data by checking initialization status.

chip ckeck.png

In-line degassing system

If you use the iMSPR Pro series, degassing the buffer is unnecessary. The built-in degassing module reduces the failure rate of experiments by removing bubbles.

Pump

Vaccum

Removed bubbles

Permeable tubing

Sensor

What are the differences between iMSPR Pro Series

Pro2X

ProX

Pro

Sample flow channel

4

two experiments per chip

Fluidics module

UFD Fluidics module with dual U-type flow cells 

Sample injection

Autosampler with dual injection valve

48 vials rack x 2

96 well plate x 2

Sample volume

(200ul sample loop)

Max 200ul

Partial injection available

30 ~ 75 ul dead volume

Screening capacity

300 samples per day

2

one experiment per chip

Standard Fluidics module with mono U-type flow cells 

1xutype.png

Autosampler with mono injection valve

48 vials rack x 2

96 well plate x 2

Max 200ul

Partial injection available

30 ~ 75 ul dead volume

150 samples per day

2

one experiment per chip

Standard Fluidics module with mono U-type flow cells

1xutype.png

Syringe

One by one

Max 200ul

Partial injection available

30 ~ 60 ul dead volume

Not recommended

UFD fluidics module

1000 x 150 um

Flow cell cross section of Standard fluidics module

700 x 50 um

Flow cell cross section of UFD fluidics module

Compare with Standard fluidics

  • 200 nl, 80% reduction of cell volume

  • Interval-less referencing

  • Lower consumption of sample

  • More accurate leveling of immobilization

Add options,

get powerful functions

Temperature control unit

 

In various temperature environments (10 to 40 degrees, room temperature dependent conditions), it is possible to obtain the value of the bonding properties and obtain the thermodynamic constants (enthalpy, entropy) through this. as well as biological temperatureThe binding properties of new drug candidates can be confirmed in the environment (37 degrees). Through this, predict the dynamics of the drug​ in the body and understand the bonding between molecules more completely.

TCU상징.png

10 C  ~

o

40 C

o

Cooling unit

When a large amount of sample needs to be analyzed, drug candidates such as antibodies may be denatured due to the high temperature inside the autosampler. The cooling unit is a temperature cooling function inside the autosampler that can prevent this. It can cool down to 4 degrees, so you can safely analyze your samples until the end. 

TCU상징.png

4 C

o

GxP Program

21 CFR compliance compliant programs can be installed. 

21 CFR part 11

Premium maintenance program

If you upgrade to iMcare+, a premium maintenance/management program, you can extend the warranty period to 2 years, as well as receive regular inspection, SW upgrade, free replacement of consumables and free operation training for 10 years.

SPR premium care service

Specifications

Pro2X

ProX

Pro

Common Includings

Individual Includings

iMSPR-Pro main body (1 set), Prism holder (1ea), Detach tool (1ea), PC (1ea), SW (1cp), Flat tweezer (1ea), Matching oil (3ml), USB cable (1ea), Power cable (1ea)

UFD Fluidics module with dual U-type flow cells (1ea), Autosampler with dual injection valve (1ea), 48 vial rack (1ea), Vials of 750ul (1pk)

Standard Fluidics module with mono U-type flow cells (1ea), Autosampler (1ea), 48 vial rack (1ea), Vials of 750ul (1pk)

Standard Fluidics module with mono U-type flow cells (1ea), Syringe of 250ul (1ea)

Waranty

SPR system

1 years

SPR type

Angular interrogation, Prism coupling

Light source

Near IR LED

Detector

Association range

Dissociation range

Affinity range

2D CMOS image sensor (The detailed specification of each model is different.)

10

3

10

7

to

M

-1

s

-1

10

-5

1

to

s

-1

10

-3

10

-12

to

M

-1

Noise level

0.1 RU

Sample type

Small compounds, peptides, oligomers, lipids, proteins, cell-like molecules

DMSO resistance

10%

bottom of page